Field test locates passive intermodulation source
The MW8219A PIM Master field test solution is designed to accurately and quickly locate the source of passive intermodulation (PIM), whether at the base station or in the surrounding environment.
Covering the PCS and AWS cellular frequency ranges, the MW8219A provides field personnel with a test system that can help ensure optimum network performance and also locate PIM faults before intermodulation distortion adversely affects signal transmission.
PIM Master has been designed to work with Anritsu's S332E/S362E Site Master, MS2712E/MS2713E Spectrum Master and MT8212E/MT8213E Cell Master handheld analysers, as well as the MT8221B/MT8222A/MT8222B BTS Master handheld analysers.
Field personnel can use the PIM Master to generate two high-power tones in the transmit band of a base station and use any of the handheld analysers to measure the third, fifth or seventh order intermodulation products in the receive band that travel down the same cable.
Using the GPS option available on all the analysers, the location of the measurement can be recorded as well.
A feature of the MW8219A is its 40W testing, compared with alternative methods that only measure at 20W.
Using double the power allows the PIM Master to locate intermittent failures due to light corrosion, high-traffic loading, or changing weather conditions.
It also permits users to find faults in a multicarrier antenna system or discover microscopic arcing in connectors.
Locating PIM Sources, Anritsu developed a proprietary technology called Distance-to-PIM for use with PIM Master.
Distance-to-PIM helps field engineers, technicians and contractors pinpoint passive intermodulation faults, eliminating the unknown of whether the PIM source is from the antenna system or surrounding environment.
Simple, immediate and accurate, Distance-to-PIM simultaneously informs the user of the distance and magnitude of all the PIM sources, both inside and beyond the antenna.
Distance-to-PIM testing provides the detail and insight that can quicken repairs, control repair costs and help plan budgets.
Historical data can be used to monitor a device and determine if it is deteriorating with age, so that corrections can be made before a failure results in dropped or blocked calls.
Not what you're looking for? Search the site.
Browse by category
- Active components (13564)
- Passive components (3589)
- Design and development (10253)
- Enclosures and panel products (3987)
- Interconnection (3648)
- Electronics manufacturing, packaging (3485)
- Industry news (2106)
- Optoelectronics (1959)
- Power supplies (3013)
- Subassemblies (5628)
- Test and measurement (5791)