News Release from: American Power Conversion | Subject: NetworkAIR RM air distribution unit
Edited by the Electronicstalk Editorial Team on 14 October 2002
Air distribution unit
keeps racks cooler
American Power Conversion has developed a novel compact air distribution unit that gives IT, telecomms and facility managers the ability to increase airflow inside racks and enclosures
American Power Conversion (APC) has developed a novel compact air distribution unit that gives IT, telecomms and facility managers the ability to increase airflow inside racks and enclosures. The latest generation of rack-based hardware - such as web servers, telecomms equipment, and internetworking hardware - continue to put more processing power into smaller physical packages allowing more equipment to be housed in a typical rack-enclosure.
Related stories
Cooling unit takes the heat off data centre racks
American Power Conversion has announced the availability of InfraStruXure InRow RP, its new innovative cooling unit for data centres and small computer rooms
UPS systems promise cost-effective protection
UPS family provides continuous power and hardware protection for desktop computers, removing the risk of lost data and downtime due to power outages and other transients
As a result, the power densities of rack-based equipment are increasing at an alarming rate and supplying the necessary air for cooling is quickly becoming one of the main concerns for today's data centre manager.
Traditional raised-floor distribution methods are currently unable to distribute enough airflow inside densely populated rack enclosures, where the cooling is most needed.
APC's NetworkAIR RM air distribution unit works in tandem with the existing precision air conditioning system to pull air from beneath the raised floor directly into the rack enclosure before it can mix with room air.
Further reading
Programme cuts the cost of UPS upgrades
The 'Trade-UPS' programme enable resellers to deliver additional value to their customers by offering to trade in old UPS in exchange for an eye-catching discount off the price of a new APC UPS
This dual fan unit works to eliminate dangerous hot spots by boosting the conditioned air volume within the rack itself and improves air delivery in poor static pressure areas.
In environments without raised floors, APC's NetworkAIR RM air distribution unit uses supply air from under and around the bottom of the rack or enclosure where the air is coldest.
This boosts the amount of air supplied to ensure necessary amounts of airflow to equipment.
"The equipment in the top portion of rack enclosures are failing at higher rates because heat rises and the intake air is above the manufacturer's recommended operating temperature", said Michael Adams.
"Hardware failures caused by excessive heat are a leading cause of downtime.
This product gives our customers a simple, reliable solution that can be installed in minutes".
This new unit ensures continuous availability by providing redundancy through dual blower fans and A-B power input feeds.
This rack-mounted solution prevents conditioned air from mixing with warmer room air before it reaches equipment and provides greater air volume than traditional perforated floor tiles.
Filtration of air before distribution into the enclosure provides additional protection against particulate contamination in sensitive equipment.
The APC NetworkAIR RM Series distribution unit is currently available in North America, and will carry an estimated reseller price of GBP 484.
• American Power Conversion: contact details and other news
• Email this article to a colleague
• Register for the free Electronicstalk email newsletter
• Electronicstalk Home Page
Related Business News
Taiwan Shares Climb 0.9 Percent
Taiwan shares rose on Thursday as investors were cheered by U.S. stock gains overnight. The Weighted Price Index of the Taiwan Stock Exchange rose 49.39 points, or 0.9 percent, to close at 8061.28.
Acxiom Agrees to Be Acquired by...
...Silver Lake and ValueAct Capital for $3.0 Billion. Acxiom Corporation announced today that it has entered into a definitive agreement to be acquired by Silver Lake, the leading investment firm focused on large-scale investments in technology-driven growth industries, and ValueAct
Opnext Reports Fourth Quarter and Full Year Operating Results
Opnext, Inc. , a global leader in the design and manufacturing of optical modules and components, today announced preliminary and unaudited financial results for the fourth quarter and full year ended March 31, 2007.
Vista Partners Updates Coverage on TXP...
...Corporation; Maintains $0.80 Price Target. Vista Partners announced today that it has update coverage on TXP Corporation . Vista Partners provides equity research to institutional and individual investors, with a focus on publicly traded small capitalization companies.
Ceasefire in Gaza Strip begins to...
...take hold ahead of Abbas visit. Gaza City, Gaza Strip (AP) - A tenuous ceasefire between rival Fatah and Hamas forces appeared to be holding Thursday, and shellshocked residents emerged from their homes to stock up on food and supplies after four days of intense fighting brought the ci